Labonce Walk-In Stability Chamber
Product categories
Latest product

View :

  • Stability chamber
    Comprehensive Stability Chamber(Double case)
    Humidity:20~95%RH Capacity:520~620L
  • Stability chamber
    Comprehensive Stability Chamber(Double case)
    Humidity:20~95%RH Capacity:520~620L
  • Photo-stability Chamber(TPS Series)
    Photo-stability Chamber(TPS Series)
    labonce-TPS series photo-stability chamber is equipped with visible  and near-ultraviolet light tubes, can independently control the type of light source, and can real -time printing and recording of visible light and near- UV radiation. visible light and near- ultraviolet can be set directly and adjusted automatically to precisely control both light sources. ◆ Equipped with D65 light source, near ultraviolet wavelength 320-400nm; ◆ Reference Standard: ICHQ1B、Chinese Pharmacopoeia 2020 edition; ◆ Light source design: The use of reasonable light source top design, the shelves of different positions of the sample to receive the light source irradiation of good uniformity; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system: Imported fully enclosed compressor, high efficiency, low noise, long service life; ◆ Control system: Programmable color touch screen controller, with three levels of user rights and audit trail function; ◆ Data management :Configure needle type micro printer and electronic data storage function,support to use U disk to export the data. ◆ Safety device: Compressor overheat and overpressure overload protection, independent overtemperature protection alarm system; ◆ Alarm system:On-site beeping alarm; ◆ Double Door Structure:Interior door tempered glass door,Open the outer door to observe the samples,The temperature inside the container will not change in a short time,The outer door is solid can keep  temperature ,It can also prevent the influence of external light; ◆ Other configurations:Test hole、Rubber plug、Mobile casters; ◆ Illumination open:Temperature Fluctuation <  ±1.0℃,Temperature deviation of the same layer: <  ±2.0℃ ; ◆ Environment Temperature:+5  ~  35℃ ; ◆ Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Remarks Labonce-150TPS-1 15 ~  50 150 650×490×500 830×790×1250 1.2 1   layer of light, Visible Light+UVA Labonce-300TPS-2 15 ~  50 300 550×660×770 850×1030×1570 1.5 2  layers of light, Visible Light+UVA Labonce-500TPS-2 15 ~  50 500 660×680×1110 880×1080×1880 1.8 2  layers of light, Visible Light+UVA Labonce-500TPS-3 15 ~  50 500 660×680×1110 880×1080×1880 2.1 3  layers of light, Visible Light+UVA Labonce-1000TPS-3 15 ~  50 1000 1360×490×1360 1620×910×1990 2.5 3  layers of light, Visible Light+UVA Labonce-150LTPS-1 2 ~ 30 150 650×490×500 830×790×1250 1.5 1   layer of light, Visible Light+UVA Labonce-500LTPS-2 2 ~ 30 500 660×680×1110 880×1080×1880 2.1 2  layers of light, Visible Light+UVA Remarks TPS:Visible Range:100 ~  8000Lux,Direct Setting,Illuminance deviation:4500±500Lux;UVA range:0.84 ~  5w/m2;        LTPS:Visible Range:100 ~  5000Lux,Direct Setting,Illuminance deviation:4500±500Lux;UVA range:0.84 ~ 1w/m2;        Illumination requirements:The total illumination is not less than 1.2×106  Lux •hr; UVA energy is not less than 200w •hr/ m2.
  • LGS series: Special for medicine packages
    Stability Chamber(LGS series: Special for medicine packages)
    Labonce - LGS  series  medicine  stability chamber  is equipped with  ultra - low  humidity control function, which  meets the requirements of the 2020 Pharmacopoeia and is suitable for GMP and CGMP certified users. ◆ Reference Standard:ICHQ1(A)、Chinese Pharmacopoeia 2020 edition; ◆ Ultra low humidity, special conditions for cartridge testing; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Control system:Programmable color touch screen controller; ◆ Refrigeration system: Imported fully enclosed compressor, high efficiency, low noise, long service life; ◆ Data management :Configure needle type micro printer and electronic data storage function,support to use U disk to export the data. ◆ Safety device: compressor overheat and overpressure overload protection, water shortage protection, dry burning protection system, independent overtemperature protection alarm system; ◆ Alarm system:On-site beeping alarm; ◆ Double Door Structure:Interior door tempered glass door,Open the outer door to observe the samples,The temperature and humidity inside the container will not change in a short time,The outer door is solid can keep temperature and humidity,It can also prevent the   influence of external light; ◆ Other configurations:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Special indicators: able to meet 60℃ /10%RH, 25℃ /20%RH special conditions (ambient temperature below 25℃ ); ◆ Controlling Temperature Precision:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±1.0℃ ; ◆ Controlling Humidity Precision:Humidity Fluctuation <  ±3%RH;Humidity Deviation <  ±3%RH; ◆ Environment Temperature:+5  ~  35℃ ; ◆ Power:AC220V±10% 50HZ. ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Model Temperature Range ( ℃ ) Humidity Range (RH) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf    (Standard) Remarks Labonce-250LGS 15 ~  65 10 ~  90% 250 600×500×830 780×880×1650 1.5 3 Single(Temperature+Humidity) Labonce-500LGS 15 ~  65 10 ~  90% 500 680×680×1080 860×1050×1850 2.2 4 Single(Temperature+Humidity) Labonce-520LGS 15 ~  65 10 ~  90% 250 600×500×830 1610×870×1650 3.0 3 A(Temperature+Humidity) 250 600×500×830 3 B(Temperature+Humidity) Labonce-520LCGS 15 ~  65 10 ~  90% 250 600×500×830 1610×870×1650 3.5 3 A(Temperature+Humidity+Visible Light+UVA) 250 600×500×830 3 B(Temperature+Humidity)   Remarks LCGS series: A chamber with temperature, humidity, visible light, UVA four functions, illuminance measurement standard with visible light and UVA     sensor, the visible light value and UVA value are automatically printed and stored; visible light range: 100 ~ 8000Lux, 4500 ± 500Lux, Total illuminance of the light test is not less than 1.2×106 Lux-hr; UVA range: 0.84 ~ 5w/ ㎡ , UVA total energy of not less than 200w-hr/ ㎡ ;When there is no light, the   temperature and humidity indicators are the same as LGS.
  • Low-temperature Stability Chamber(BC/RC/FC Series)
    Low-temperature Stability Chamber(BC/RC/FC Series)
    Labonce -C Series  Low -temperature Stability Chamber,Adopt the  brand - new air-way structural design, select the original imported high quality parts and manufacturing process, ensure the long -term continuous operation of the equipment, stable and reliable performance, suitable for temperature sensitive medicine stability test and preservation. ◆ Reference Standard:Medical refrigerator industry standard: YY/T 0086-2020; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:Original imported digital display controller, high precision, low drift; ◆ Safety device: compressor overheat and overpressure overload protection; ◆ Alarm system:On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Controlling Temperature Precision:BC:Temperature Fluctuation <  ±1.0℃;Temperature Deviation <  ±2.0℃;Temperature Uniformity ≤ 2.0℃ ; RC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±1.0℃ ; Temperature Uniformity ≤ 1.0℃ ; FC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±2.0℃ ; Temperature Uniformity ≤ 2.0℃ ; ◆ Environment Temperature:+5 ~  30℃ ;        Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf     (Standard) Remarks     Storage Chamber (2~14℃ ) Labonce-250BC 2~14 250 600×500×830 780×880×1650 0.6 3     With observation window Labonce-400BC 2~14 400 600×700×950 780×1060×1750 0.8 3 Labonce-500BC 2~14 500 680×680×1080 860×1050×1850 1.0 4 Labonce-800BC 2~14 800 1200×490×1360 1390×890×1960 1.2 4 Labonce-1000BC 2~14 1000 1400×510×1400 1590×890×1980 1.5 4   Low-temperatre Chamber(5℃ ) Labonce-250RC 5 250 600×500×830 780×880×1650 0.6 3 With observation  window,Double  compressors, one operation and one protection. Labonce-500RC 5 500 680×680×1080 860×1050×1850 1.2 4 Labonce-720RC 5 750 1200×490×1360 1390×890×1960 1.5 4 Labonce-2000RC 5 2000 1500×970×1400 1710×1380×1990 2.0 4 Low-temperatre Chamber(-20℃ ) Labonce-150FC -20 150 600×405×620 850×890×1520 1.0 3 Solid door Labonce-250FC -20 250 600×500×830 850×990×1690 1.5 3
1 2 3 4 5 >>

A total of 5pages

Beijing Labonce Themostatic Technology Company

Professional Technology , Good Products

Email: export@labonce.com FDA/ICH stability Chamber

© 2008-2024 Beijing Labonce Themostatic Technology Company All Rights Reserved

Online contact

Online contact

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!