Labonce Walk-In Stability Chamber
Product categories
Latest product
LGS series: Special for medicine packages

Stability Chamber(LGS series: Special for medicine packages)

  • Item NO.:

    250-500LGS
Product introduction

Labonce - LGS  series  medicine  stability chamber  is equipped with  ultra - low  humidity control function, which  meets the requirements of the 2020 Pharmacopoeia and is suitable for GMP and CGMP certified users.

◆ Reference Standard:ICHQ1(A)、Chinese Pharmacopoeia 2020 edition;

◆ Ultra low humidity, special conditions for cartridge testing;

◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance;

◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean;

◆ Control system:Programmable color touch screen controller;

◆ Refrigeration system: Imported fully enclosed compressor, high efficiency, low noise, long service life;

◆ Data management Configure needle type micro printer and electronic data storage function,support to use U disk to export the data.

◆ Safety device: compressor overheat and overpressure overload protection, water shortage protection, dry burning protection system, independent overtemperature protection alarm system;

◆ Alarm system:On-site beeping alarm;

◆ Double Door Structure:Interior door tempered glass door,Open the outer door to observe the samples,The temperature and humidity inside the container will not change in a short time,The outer door is solid can keep temperature and humidity,It can also prevent the   influence of external light;

◆ Other configurations:Test hole、Rubber plug、Mobile casters、Door lock;

◆ Special indicators: able to meet 60℃ /10%RH, 25℃ /20%RH special conditions (ambient temperature below 25℃ );

◆ Controlling Temperature Precision:Temperature Fluctuation   ±0. 5℃;Temperature Deviation   ±1.0℃ ;

◆ Controlling Humidity Precision:Humidity Fluctuation   ±3%RH;Humidity Deviation   ±3%RH;

◆ Environment Temperature+5  ~  35℃ ;

◆ Power:AC220V±10% 50HZ.

◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm.

Model

Temperature Range ( ℃ )

Humidity Range (RH)

Capacity

(L)

Interior

Dimensions(mm)

D×H

External Dimensions(mm)

D×H

Power

( kW )

Shelf    (Standard)

Remarks

Labonce-250LGS

15 ~  65

10 ~  90%

250

600×500×830

780×880×1650

1.5

3

Single(Temperature+Humidity)

Labonce-500LGS

15 ~  65

10 ~  90%

500

680×680×1080

860×1050×1850

2.2

4

Single(Temperature+Humidity)

Labonce-520LGS

15 ~  65

10 ~  90%

250

600×500×830

1610×870×1650

3.0

3

A(Temperature+Humidity)

250

600×500×830

3

B(Temperature+Humidity)

Labonce-520LCGS

15 ~  65

10 ~  90%

250

600×500×830

1610×870×1650

3.5

3

A(Temperature+Humidity+Visible Light+UVA)

250

600×500×830

3

B(Temperature+Humidity)

 

Remarks

LCGS series: A chamber with temperature, humidity, visible light, UVA four functions, illuminance measurement standard with visible light and UVA     sensor, the visible light value and UVA value are automatically printed and stored; visible light range: 100 ~ 8000Lux, 4500 ± 500Lux, Total illuminance of the light test is not less than 1.2×106 Lux-hr; UVA range: 0.84 ~ 5w/ ㎡ , UVA total energy of not less than 200w-hr/ ㎡ ;When there is no light, the   temperature and humidity indicators are the same as LGS.

Related products
  • Constant Temperature & humidity chamber Constant Temperature & humidity chamber(≥800L)

    Humidity:40~95%RH Capacity:800L~2000L

  • Medicine high-light stability chambers Medicine high-light stability chambers

    Temperature:2~30 Capacity:150L~250L

  • Low-temperature Stability Chamber(BC/RC/FC Series) Low-temperature Stability Chamber(BC/RC/FC Series)

    Labonce -C Series  Low -temperature Stability Chamber,Adopt the  brand - new air-way structural design, select the original imported high quality parts and manufacturing process, ensure the long -term continuous operation of the equipment, stable and reliable performance, suitable for temperature sensitive medicine stability test and preservation. ◆ Reference Standard:Medical refrigerator industry standard: YY/T 0086-2020; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:Original imported digital display controller, high precision, low drift; ◆ Safety device: compressor overheat and overpressure overload protection; ◆ Alarm system:On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Controlling Temperature Precision:BC:Temperature Fluctuation <  ±1.0℃;Temperature Deviation <  ±2.0℃;Temperature Uniformity ≤ 2.0℃ ; RC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±1.0℃ ; Temperature Uniformity ≤ 1.0℃ ; FC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±2.0℃ ; Temperature Uniformity ≤ 2.0℃ ; ◆ Environment Temperature:+5 ~  30℃ ;        Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf     (Standard) Remarks     Storage Chamber (2~14℃ ) Labonce-250BC 2~14 250 600×500×830 780×880×1650 0.6 3     With observation window Labonce-400BC 2~14 400 600×700×950 780×1060×1750 0.8 3 Labonce-500BC 2~14 500 680×680×1080 860×1050×1850 1.0 4 Labonce-800BC 2~14 800 1200×490×1360 1390×890×1960 1.2 4 Labonce-1000BC 2~14 1000 1400×510×1400 1590×890×1980 1.5 4   Low-temperatre Chamber(5℃ ) Labonce-250RC 5 250 600×500×830 780×880×1650 0.6 3 With observation  window,Double  compressors, one operation and one protection. Labonce-500RC 5 500 680×680×1080 860×1050×1850 1.2 4 Labonce-720RC 5 750 1200×490×1360 1390×890×1960 1.5 4 Labonce-2000RC 5 2000 1500×970×1400 1710×1380×1990 2.0 4 Low-temperatre Chamber(-20℃ ) Labonce-150FC -20 150 600×405×620 850×890×1520 1.0 3 Solid door Labonce-250FC -20 250 600×500×830 850×990×1690 1.5 3

  • MIT Series/MIS Series Mold Incubator(150MIT~800MIT)

    TEMP: 0-60°CCapacity:150~250L

  • MIT Series/MIS Series Mold Incubator(150MIT~800MIT)

    TEMP: 0-60°CCapacity:150~250L

  • CT Series Constant Temperature Chamber(800CT~1000CT)

    TEMP:  0~85℃ CAPACITY: 800L~1000L

  • High and low temperature alternating chamber Programmable Temperature & Humidity Chamber

    TEMP:-20~150℃;-40~150℃;-60~150℃

  • Walk-in stability chamber Walk-in Environmental Chamber

    Humidity:40~80%RH Capacity:33000L

  • Constant Temperature & humidity chamber Constant Temperature & humidity chamber(≥800L)

    Humidity:40~95%RH Capacity:800L~2000L

  • Medicine high-light stability chambers Medicine high-light stability chambers

    Temperature:2~30 Capacity:150L~250L

  • Low-temperature Stability Chamber(BC/RC/FC Series) Low-temperature Stability Chamber(BC/RC/FC Series)

    Labonce -C Series  Low -temperature Stability Chamber,Adopt the  brand - new air-way structural design, select the original imported high quality parts and manufacturing process, ensure the long -term continuous operation of the equipment, stable and reliable performance, suitable for temperature sensitive medicine stability test and preservation. ◆ Reference Standard:Medical refrigerator industry standard: YY/T 0086-2020; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:Original imported digital display controller, high precision, low drift; ◆ Safety device: compressor overheat and overpressure overload protection; ◆ Alarm system:On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Controlling Temperature Precision:BC:Temperature Fluctuation <  ±1.0℃;Temperature Deviation <  ±2.0℃;Temperature Uniformity ≤ 2.0℃ ; RC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±1.0℃ ; Temperature Uniformity ≤ 1.0℃ ; FC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±2.0℃ ; Temperature Uniformity ≤ 2.0℃ ; ◆ Environment Temperature:+5 ~  30℃ ;        Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf     (Standard) Remarks     Storage Chamber (2~14℃ ) Labonce-250BC 2~14 250 600×500×830 780×880×1650 0.6 3     With observation window Labonce-400BC 2~14 400 600×700×950 780×1060×1750 0.8 3 Labonce-500BC 2~14 500 680×680×1080 860×1050×1850 1.0 4 Labonce-800BC 2~14 800 1200×490×1360 1390×890×1960 1.2 4 Labonce-1000BC 2~14 1000 1400×510×1400 1590×890×1980 1.5 4   Low-temperatre Chamber(5℃ ) Labonce-250RC 5 250 600×500×830 780×880×1650 0.6 3 With observation  window,Double  compressors, one operation and one protection. Labonce-500RC 5 500 680×680×1080 860×1050×1850 1.2 4 Labonce-720RC 5 750 1200×490×1360 1390×890×1960 1.5 4 Labonce-2000RC 5 2000 1500×970×1400 1710×1380×1990 2.0 4 Low-temperatre Chamber(-20℃ ) Labonce-150FC -20 150 600×405×620 850×890×1520 1.0 3 Solid door Labonce-250FC -20 250 600×500×830 850×990×1690 1.5 3

  • MIT Series/MIS Series Mold Incubator(150MIT~800MIT)

    TEMP: 0-60°CCapacity:150~250L

  • MIT Series/MIS Series Mold Incubator(150MIT~800MIT)

    TEMP: 0-60°CCapacity:150~250L

  • CT Series Constant Temperature Chamber(800CT~1000CT)

    TEMP:  0~85℃ CAPACITY: 800L~1000L

  • High and low temperature alternating chamber Programmable Temperature & Humidity Chamber

    TEMP:-20~150℃;-40~150℃;-60~150℃

  • Walk-in stability chamber Walk-in Environmental Chamber

    Humidity:40~80%RH Capacity:33000L

Beijing Labonce Themostatic Technology Company

Professional Technology , Good Products

Email: export@labonce.com FDA/ICH stability Chamber

© 2008-2025 Beijing Labonce Themostatic Technology Company All Rights Reserved

Online contact

Online contact

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!