Humidity:10~90%RH
Chamber capacity: Customized
Temperature control: Customized
Humidity control: Customized
Capacity:Design
Power supply: AC 220V±10%, 50Hz
Operating environment: +5-35°C
The Labonce-CGS-T Series Customized Pharmaceutical Stability Test Chamber is designed for various compliant testing applications, including long-term, accelerated, and intermediate stability testing. It typically offers a temperature range of 0°C to 65°C and a humidity range of 45% RH to 95% RH, with adjustable parameters to meet specific testing requirements.
1. Controller: Programmable color touchscreen (≥7"), with three-level access control,
2. Humidity sensor: Imported capacitive sensor (direct detection, maintenance-free),
3. Compressor: Imported hermetic compressor (long lifespan, low noise),
4. Data printing: Prints device model/serial number plus temperature/humidity values and curves,
5. Data storage: Stores temperature/humidity data for 5+ years,
6. On-site alarms: Audible alarms for parameter deviations and independent overtemperature alarm,
7. Remote alarm: SMS alerts (including power failure), supports multiple devices per SIM card,
8. Construction: 304 stainless steel interior (mirror finish), powder-coated steel exterior,
9. Dual protection: Dry-burn prevention system + independent overtemperature protection with auto power cutoff,
10. Safety features: Compressor overheat/overpressure/overload protection + fan overheat protection.
Previous :
Stability Chamber(3000L)Next :
Stability Test Chamber (Triple Independent)
Stability Chamber(>800L)
Humidity:15~95%RH Capacity:800~1000L Power: AC220V±10% 50Hz/60Hz Environment Temperature:+5 ~ 35℃ Temperature Fluctuation<±0.5℃ Temperature Uniformity <±1.0℃ Humidity Fluctuation < ±2%RH Humidity Uniformity < ±3%RH
Stability Test Chamber (Triple Independent)
Chamber capacity: 430L-930L Humidity control: Range 20-95%RH Temperature control: Range 15-65°C Power: AC 220V±10%, 50Hz Visible light: 100-6,000 Lux Near-UV: 0.84-1 W/m² UV wavelength: 320-400 nm
Stability Test Chamber(UVA)
Humidity: 20~95%RH Internal Volume: 150L–500L Power Supply: AC 220V±10%, 50Hz Temperature Control: Range: 15–65°C Fluctuation: ±0.5°C Deviation: ±1.0°C (without light)
Stability Chamber(3000L)
Capacity: 3000L Humidity: 15~95%RH Environment Temperature: +5 ~ 35℃ Temperature Fluctuation<±0.5℃ Temperature Uniformity <±1.0℃ Humidity Fluctuation < ±2%RH Humidity Uniformity < ±3%RH Power: AC220V±10% 50Hz/60Hz
Stability Test Chamber(Dual Independent)
Humidity:20~95%RH Internal Volume: 300L-600L Temperature Control Range: 15-65°C Temperature Fluctuation: ±0.5°C Temperature Deviation: ±1.0°C (without light) Humidity Control Range: 20-95%RH Humidity Fluctuation: ±2.0%RH Humidity Deviation: ±3.0%RH Power Supply: AC 220V±10%, 50Hz
Stability Chamber(<500L)
Humidity: 15~95%RH Capacity: 150~500L Temperature Fluctuation: <±0.5℃ Temperature Uniformity: <±1.0℃ Humidity Fluctuation: < ±2%RH Humidity Uniformity: < ±3%RH Power: AC220V±10% 50Hz/60Hz Environment Temperature: +5 ~ 35℃
Stability Test Chamber(UVA)
Humidity: 20~95%RH Internal Volume: 150L–500L Power Supply: AC 220V±10%, 50Hz Temperature Control: Range: 15–65°C Fluctuation: ±0.5°C Deviation: ±1.0°C (without light)