Labonce Walk-In Stability Chamber
Product categories
Latest product
Stability Test Chamber
Stability Test Chamber
Stability Test Chamber
Stability Test Chamber

Stability Chamber(>800L)

Humidity:15~95%RH Capacity:800~1000L
  • Item NO.:

    800-1000GS-FC
  • Product Origin:

    CHINA
Product introduction

Labonce-GS-FC Stability Chamber, Adopt imported with frequency conversion technology design, Choose the original imported high quality parts, Stable and reliable performance,Suitable for GMP and CGMP certified users.



 Reference Standard:ICHQ1、Chinese Pharmacopoeia 2025 edition; 
 Insulation material: Overall high-density polyurethane foam technology. Good insulation and moisture             retention performance; 
 Chamber Materials: The exterior material is coated with high quality steel plate. Inner material is made of            stainless steel 304, no pollution source, easy to clean; 
 Control system: More than 7 inches programmable color touchscreen controller, display frequency                      conversion output data; 
 Three Level Authority: Adopt the user name and password to log in. Different user names have different            permissions at least three levels or above; 
 Audit tracking: The control system has historical alarm recording and operation recording functions.                   Supports exporting in an unchangeable file format using a USB flash drive; 
  Refrigeration system: Imported fully enclosed compressor with frequency conversion, save more than 50%         of electricity and water; 
 Humidity control: Original imported capacitive humidity sensor, high precision, low drift, long service life; 
 Data management: configuring needle micro printers and electronic data storage functions
 Safety device: Compressor overheat and overpressure overload protection, water shortage protection.                 Anti dry burning protection system, independent overtemperature protection alarm system; 
 Alarm system:On-site audible & visual alarm; 
 Double Door structure:Interior door tempered glass door. Open the outer door to observe the sample.           Temperature and humidity inside the container will not change in a short time. Outer door is solid can               keep temperature and humidity. Can also prevent the influence of external light; 
 Controlling Temperature Precision:Temperature Fluctuation<±0.5℃;Temperature Uniformity <±1.0℃ ; 
 Controlling Humidity Precision:Humidity Fluctuation < ±2%RH;Humidity Uniformity <  ±3%RH; 
⓯ Power:AC220V±10% 50Hz/60Hz; 
⓰  Environment Temperature:+5  ~  35℃ ; 
  Optional: Temperature- humidity deviation, sudden power failure, remote SMS alarm.

 Special Note: Online consultation below the PDF and WORD iconyou can download this page of the color page related materials.


Model

Temperature Range( ℃ )

Humidity Range (RH)

Capacity

(L)

Interior Dimensions

W×D×H(mm)

External Dimensions

W×D×H(mm)

Power

(kW)

Shelf (Standard)

Remarks

Labonce-800GS-FC

10~65

15~95%

800

1200×490×1360

1385×895×1965

2.5

4/8

Customized

observation

window

Labonce-1000GS-FC

10~65

15~95%

1000

1400×510×1400

1615×925×1975

3.0

4/8



SEND A MESSAGE

Related products
  • Comprehensive Stability Chamber Stability Test Chamber (Triple Independent)

    Humidity:20~95%RH Capacity:400~900L

  • Stability chamber Stability Test Chamber(UVA)

    Humidity:20~95%RH Capacity:150L~500LUVA

  • Stability chamber Stability Test Chamber(Dual Independent)

    Humidity:20~95%RH Capacity:320~620L

  • Stability Chamber, Stability test chamber Stability Chamber(<500L)

    Humidity:15~95%RH Capacity:150~500L

  • Temperature Humidity Stability Test Chamber Stability Chamber(3000L)

    Humidity:15~95%RH Capacity:3000L

  • Stability Test Chamber(Special design) Stability Test Chamber(Special design)

    Humidity:10~90%RH Capacity:Design

  • BI Series Biochemical Incubator(BI Series)

    Labonce- BI series of biochemical incubator is applied in scientific research and production departments such as environmental protection, health and epidemic prevention, agriculture, animal husbandry, and aquatic products, drug testing, and cell culture. ◆ Reference standard: GB/T 28851-2012 Technical conditions for biochemical incubators; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:LCD temperature controller; ◆ Data management :Configure needle type micro printer and electronic data storage function,support to use U disk to export the data; ◆ Safety device: compressor overheat and overpressure overload protection, independent overtemperature protection alarm system,On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters; ◆ Controlling Temperature Precision:Temperature Fluctuation:High temperature ±0. 5℃;   Low temperature  ±1.0℃ ; Temperature Uniformity  ≤ 2.0℃(@37℃); ◆ Environment Temperature:+5 ~  35℃ ; ◆ Power:AC220V±10% 50HZ; ◆ Optional: ① UV sterilization system;             ② Three- level permission color touch screen controller; ③ SMS alarm;                                  ④ Humidity display function. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf     (Standard) Remarks       Biochemical Incubator Labonce-150BI 0 ~  60 150 520×460×600 640×700×1250 0.5 3 150-250L Configure obser vation window Labonce-250BI 0 ~  60 250 520×460×1050 620×690×1650 0.6 3 Labonce-400BI 0 ~  60 400 600×700×950 780×1060×1750 1.0 3   400-2000L Configured with built-in glass doors Labonce-500BI 0 ~  60 500 680×680×1080 860×1050×1850 1.2 4 Labonce-800BI 0 ~  60 800 1200×490×1360 1390×890×1960 1.5 4 Labonce-1000BI 0 ~  60 1000 1400×510×1400 1590×890×1980 2.0 4 Labonce-2000BI 0 ~  60 2000 1500×970×1400 1710×1380×1990 2.5 4 Biochemical Incubator Labonce-250BI-H 0 ~  60 250 520×460×1050 620×690×1650 0.6 3 With humidity display Labonce-800BI-H 0 ~  60 800 1200×490×1360 1390×890×1960 1.5 4

  • Low-temperature Stability Chamber(BC/RC/FC Series) Low-temperature Stability Chamber(BC/RC/FC Series)

    Labonce -C Series  Low -temperature Stability Chamber,Adopt the  brand - new air-way structural design, select the original imported high quality parts and manufacturing process, ensure the long -term continuous operation of the equipment, stable and reliable performance, suitable for temperature sensitive medicine stability test and preservation. ◆ Reference Standard:Medical refrigerator industry standard: YY/T 0086-2020; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:Original imported digital display controller, high precision, low drift; ◆ Safety device: compressor overheat and overpressure overload protection; ◆ Alarm system:On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Controlling Temperature Precision:BC:Temperature Fluctuation <  ±1.0℃;Temperature Deviation <  ±2.0℃;Temperature Uniformity ≤ 2.0℃ ; RC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±1.0℃ ; Temperature Uniformity ≤ 1.0℃ ; FC:Temperature Fluctuation <  ±0. 5℃;Temperature Deviation <  ±2.0℃ ; Temperature Uniformity ≤ 2.0℃ ; ◆ Environment Temperature:+5 ~  30℃ ;        Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote  SMS alarm. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf     (Standard) Remarks     Storage Chamber (2~14℃ ) Labonce-250BC 2~14 250 600×500×830 780×880×1650 0.6 3     With observation window Labonce-400BC 2~14 400 600×700×950 780×1060×1750 0.8 3 Labonce-500BC 2~14 500 680×680×1080 860×1050×1850 1.0 4 Labonce-800BC 2~14 800 1200×490×1360 1390×890×1960 1.2 4 Labonce-1000BC 2~14 1000 1400×510×1400 1590×890×1980 1.5 4   Low-temperatre Chamber(5℃ ) Labonce-250RC 5 250 600×500×830 780×880×1650 0.6 3 With observation  window,Double  compressors, one operation and one protection. Labonce-500RC 5 500 680×680×1080 860×1050×1850 1.2 4 Labonce-720RC 5 750 1200×490×1360 1390×890×1960 1.5 4 Labonce-2000RC 5 2000 1500×970×1400 1710×1380×1990 2.0 4 Low-temperatre Chamber(-20℃ ) Labonce-150FC -20 150 600×405×620 850×890×1520 1.0 3 Solid door Labonce-250FC -20 250 600×500×830 850×990×1690 1.5 3

Beijing Labonce Themostatic Technology Company

Professional Technology , Good Products

Email: export@labonce.com FDA/ICH stability Chamber

© 2008-2025 Beijing Labonce Themostatic Technology Company All Rights Reserved

Online contact

Online contact

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!