Newsletter
Keep up with our latest news and events.
Enter your email and subscribe to our newsletter
Humidity:40~95%RH Capacity:150L~500L
Read more1)High precision;2)All stainless steel 304 inside and outside;. 3)Temperature:0~70℃;4)Humidity:10~80%RH.
Read moreItem NO.:
100GDJ~1000GDJProduct Origin:
CHINALabonce-GDJ series high and low temperature test box is applied to the adaptability test of electrotechnics, electronic products, their original devices, and other materials when they are stored, transported and used in high and low temperature environment. Under low temperature, high temperature and other conditions, the physical and other related characteristics of the product are simulated and tested. After the test, the performance of the product can be judged by the test and whether it still meets the predetermined requirements for product design, improvement, identification and delivery inspection.
❶ Volume: 100L~1000L;
❷ Temperature control range: GDJA: -20 ~ 150 ℃; GDJB: -40 ~ 150 ℃; GDJC: -60 ~ 150 ℃
❸ Temperature fluctuation: < ± 0.5 ℃; Rising temperature rate: 3 ℃ / min; cooling rate: 1 ℃ / min. Temperature deviation: < ±2.0℃;
❹ Temperature controller: original imported digital display controller;
❺ Refrigeration compressor: original imported hermetic compressor, long life, low noise;
❻ Data storage: U disk storage, can store more than one year temperature and humidity values;
❼ Chamber material: liner material for mirror stainless steel 304, shell material for high-quality steel spray;
❽ Safety devices: compressor overheating protection and overpressure overload protection; fan overheating protection;
❾ On-site alarm: temperature upper and lower limit deviation alarm; independent over-temperature protection alarm system;
❿ Power supply: AC 220V±10% 50Hz (AC 380V±10% 50Hz);
⓫ Special Note: Online consultation below the PDF and WORD icons, you can download the color page of this page related information.
Name |
Model |
Temp |
Capacity (L) |
Interior Dimens W×D×H(mm) |
External Dimens W×D×H(mm) |
Shelf |
Remarks |
High-low temperature chamber |
Labonce-100GDJ |
GDJA:-20~150℃ GDJB:-40~150℃ GDJC:-60~150℃ |
100 |
450×450×500 |
730×1040×1570 |
2 |
Power specs refer to the tech specs of the corresponding model |
Labonce-250GDJ |
250 |
650×550×700 |
930×1180×1850 |
2 |
|||
Labonce-500GDJ |
500 |
800×700×900 |
1250×1150×2080 |
2 |
|||
Labonce-1000GDJ |
1000 |
1000×1000×1000 |
1500×1500×2200 |
2 |
Previous :
High-Low Temperature Chamber 1000JSLabonce -C Series Low -temperature Stability Chamber,Adopt the brand - new air-way structural design, select the original imported high quality parts and manufacturing process, ensure the long -term continuous operation of the equipment, stable and reliable performance, suitable for temperature sensitive medicine stability test and preservation. ◆ Reference Standard:Medical refrigerator industry standard: YY/T 0086-2020; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:Original imported digital display controller, high precision, low drift; ◆ Safety device: compressor overheat and overpressure overload protection; ◆ Alarm system:On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters、Door lock; ◆ Controlling Temperature Precision:BC:Temperature Fluctuation < ±1.0℃;Temperature Deviation < ±2.0℃;Temperature Uniformity ≤ 2.0℃ ; RC:Temperature Fluctuation < ±0. 5℃;Temperature Deviation < ±1.0℃ ; Temperature Uniformity ≤ 1.0℃ ; FC:Temperature Fluctuation < ±0. 5℃;Temperature Deviation < ±2.0℃ ; Temperature Uniformity ≤ 2.0℃ ; ◆ Environment Temperature:+5 ~ 30℃ ; Power:AC220V±10% 50HZ; ◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote SMS alarm. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf (Standard) Remarks Storage Chamber (2~14℃ ) Labonce-250BC 2~14 250 600×500×830 780×880×1650 0.6 3 With observation window Labonce-400BC 2~14 400 600×700×950 780×1060×1750 0.8 3 Labonce-500BC 2~14 500 680×680×1080 860×1050×1850 1.0 4 Labonce-800BC 2~14 800 1200×490×1360 1390×890×1960 1.2 4 Labonce-1000BC 2~14 1000 1400×510×1400 1590×890×1980 1.5 4 Low-temperatre Chamber(5℃ ) Labonce-250RC 5 250 600×500×830 780×880×1650 0.6 3 With observation window,Double compressors, one operation and one protection. Labonce-500RC 5 500 680×680×1080 860×1050×1850 1.2 4 Labonce-720RC 5 750 1200×490×1360 1390×890×1960 1.5 4 Labonce-2000RC 5 2000 1500×970×1400 1710×1380×1990 2.0 4 Low-temperatre Chamber(-20℃ ) Labonce-150FC -20 150 600×405×620 850×890×1520 1.0 3 Solid door Labonce-250FC -20 250 600×500×830 850×990×1690 1.5 3
1)High precision; 2)All stainless steel 304 inside and outside;. 3)Temperature:0~70℃; 4)Humidity:10~80%RH.
Mold incubator MIS series is used in environmental protection, health epidemic prevention, drug testing, agriculture, livestock and aquatic research institutes. It is a special constant temperature equipment for water analysis, BOD detection, mold and other microbial culture. ❶ Internal volume: 250L~500L; ❷ Temperature control range: 50 ~ 85 ℃, temperature fluctuation: high temperature ± 0.5 ℃, low temperature ± 1 ℃; uniformity ± 2.0 ℃. ❸ Controller: microcomputer controller, sensitive sensing, small system error; ❹ Compressor: fully enclosed compressor, high efficiency, low noise; to ensure long-term continuous operation of the equipment: ❺ Data printing: optional; ❻ Lamp: with lighting, with UV sterilization lamp; ❼ Chamber material: liner material for mirror stainless steel 304, corners of the semi-circular arc, easy to clean, chamber shelf spacing adjustable; ❽ Chamber door structure: the use of double-layer tempered glass door, easy to observe the samples in the chamber; ❾ System protection: equipped with independent over-temperature protection system; ❿ Safety devices: compressor overheating protection, compressor overpressure protection, compressor overload protection and fan overheating protection. ⓫ Working environment: +5~35℃. ⓬ Power supply: AC220V±10%50Hz. ⓭ Special Note: Consult the PDF and WORD icons below online to download the color page related information on this page. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power (kW) Shelf (Standard) Remarks Mould incubator Labonce-150MIT 0 ~ 60 150 520×460×600 640×700×1250 0.5 3 With viewing window No humidity Labonce-250MIT 0 ~ 60 250 520×460×1050 620×690×1650 0.6 3 Labonce-500MIT 0 ~ 60 500 680×680×1080 860×1050×1850 1.2 4 No humidity Labonce-800MIT 0 ~ 60 800 1200×490×1360 1385×895×1965 1.5 4 Mould incubator (With humidity control) Labonce-250MIS 15 ~ 50 250 600×500×830 780×870×1650 1.5 3 Humidity range: 50-85% RH Printer options Labonce-500MIS 15 ~ 50 500 680×680×1080 860×1050×1850 2.0 4
Pay attention to WeChat