Stability Chamber(LGS series: Special for medicine packages)
Labonce - LGS series medicine stability chamber is equipped with ultra - low humidity control function, which meets the requirements of the 2020 Pharmacopoeia and is suitable for GMP and CGMP certified users.
◆ Reference Standard:ICHQ1(A)、Chinese Pharmacopoeia 2020 edition;
◆ Ultra low humidity, special conditions for cartridge testing;
◆ Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance;
◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean;
◆ Control system:Programmable color touch screen controller;
◆ Refrigeration system: Imported fully enclosed compressor, high efficiency, low noise, long service life;
◆ Data management :Configure needle type micro printer and electronic data storage function,support to use U disk to export the data.
◆ Safety device: compressor overheat and overpressure overload protection, water shortage protection, dry burning protection system, independent overtemperature protection alarm system;
◆ Alarm system:On-site beeping alarm;
◆ Double Door Structure:Interior door tempered glass door,Open the outer door to observe the samples,The temperature and humidity inside the container will not change in a short time,The outer door is solid can keep temperature and humidity,It can also prevent the influence of external light;
◆ Other configurations:Test hole、Rubber plug、Mobile casters、Door lock;
◆ Special indicators: able to meet 60℃ /10%RH, 25℃ /20%RH special conditions (ambient temperature below 25℃ );
◆ Controlling Temperature Precision:Temperature Fluctuation < ±0. 5℃;Temperature Deviation < ±1.0℃ ;
◆ Controlling Humidity Precision:Humidity Fluctuation < ±3%RH;Humidity Deviation < ±3%RH;
◆ Environment Temperature:+5 ~ 35℃ ;
◆ Power:AC220V±10% 50HZ.
◆ Optional: Temperature- humidity deviation, sudden power failure , control by Remote SMS alarm.
Model
Temperature Range ( ℃ )
Humidity Range (RH)
Capacity
(L)
Interior
Dimensions(mm)
W×D×H
External Dimensions(mm)
W×D×H
Power
( kW )
Shelf (Standard)
Remarks
Labonce-250LGS
15 ~ 65
10 ~ 90%
250
600×500×830
780×880×1650
1.5
3
Single(Temperature+Humidity)
Labonce-500LGS
15 ~ 65
10 ~ 90%
500
680×680×1080
860×1050×1850
2.2
4
Single(Temperature+Humidity)
Labonce-520LGS
15 ~ 65
10 ~ 90%
250
600×500×830
1610×870×1650
3.0
3
A(Temperature+Humidity)
250
600×500×830
3
B(Temperature+Humidity)
Labonce-520LCGS
15 ~ 65
10 ~ 90%
250
600×500×830
1610×870×1650
3.5
3
A(Temperature+Humidity+Visible Light+UVA)
250
600×500×830
3
B(Temperature+Humidity)
Remarks
LCGS series: A chamber with temperature, humidity, visible light, UVA four functions, illuminance measurement standard with visible light and UVA sensor, the visible light value and UVA value are automatically printed and stored; visible light range: 100 ~ 8000Lux, 4500 ± 500Lux, Total illuminance of the light test is not less than 1.2×106 Lux-hr; UVA range: 0.84 ~ 5w/ ㎡ , UVA total energy of not less than 200w-hr/ ㎡ ;When there is no light, the temperature and humidity indicators are the same as LGS.