Product categories
Photostability Chamber(500TPS-2)

Photostability Chamber(500TPS-2)



Internal volume: 500L
Temperature control range: 15~50℃
Temperature fluctuation: ±1.0℃
Temperature deviation: ±2.0℃ (same level)
Light range: Visible light range: 100 ~ 8000LUX
Total illumination is not less than 1.2 × 106Lux-hr
UV range: near-ultraviolet range: 0.84~5w/m²
Near-ultraviolet energy not less than 200w-hr/m²
UV wavelength: near-UV wavelength: 320~400nm

Product introduction

Labonce Photostability Test Chamber equipped with visible and near-ultraviolet lamps, can independently control the type of light source, and real-time printing and recording of visible light illuminance and near-ultraviolet radiation; visible and near-ultraviolet can be set up directly, automatically adjusted, and accurately control the two types of light sources.

Features of Photostability Test Chamber 

1. Illumination Control & Controllers
Temperature, visible light, and near-UV light can be independently set and controlled through three imported controllers.
2. Data Printing & Storage
Supports simultaneous printing of temperature, visible light, and near-UV values, with over one year of data storage.
3. Refrigeration System
Equipped with an imported hermetic compressor, ensuring long service life, stable operation, and low noise.
4. Alarm & Over-Temperature Protection
Features on-site buzzer alarms for temperature deviations and independent over-temperature protection with automatic power cut-off.
5. Multiple Safety Protections
Includes compressor overheating, overpressure, and overload protection, as well as fan overheating protection.
6. Remote Alarm (Optional)
Optional SMS remote alarm with power failure notification. Multiple units can share one SIM card for centralized alarm monitoring.

Specification of Photostability Test Chamber 

Model

Temperature Range

( ℃ )

Capacity

(L)

Interior Dimensions

W×D×H(mm)

External Dimensions

W×D×H(mm)

Power

( kW )

Remarks 1

Labonce-150TPS-1

15 ~  50

150

650×490×500

830×790×1250

1.2

1  layer of light

Labonce-300TPS-2

15 ~  50

300

550×660×770

850×1030×1570

1.5

2 layers of light

Labonce-500TPS-2

15 ~  50

500

660×680×1110

880×1080×1880

1.8

2 layers of light

Labonce-500TPS-3

15 ~  50

500

660×680×1110

880×1080×1880

2.1

3 layers of light

Labonce-1000TPS-3

15 ~  50

1000

1360×490×1360

1620×910×1990

2.5

3 layers of light

Labonce-150LTPS-1

2 ~ 30

150

650×490×500

830×790×1250

1.5

1  layer of light

Labonce-500LTPS-2

2 ~ 30

500

660×680×1110

880×1080×1880

2.1

2 layers of light

Remarks 2

Visible Range: 100 ~  8000Lux, Deviation:4500±500Lux;UVA range:0.84 ~  5w/m2; (TPS)

Visible Range: 100 ~  5000Lux, Deviation:4500±500Lux;UVA range:0.84 ~ 1w/m2; (LTPS)

The total illumination ≥ 1.2×106 Lux •hr; UVA energy ≥ 200w •hr/ m2

Each of layer of light: Visible Light+UVA






SEND A MESSAGE

Related products
  • Photostability Chamber Photostability Chamber(150LTPS-1)

    Internal volume: 150L Temperature control range: 2~30℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃ (same level) Light range: Visible light range: 100 ~ 6000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~1w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability chamber Photostability Chamber(150TPS-1)

    Internal volume: 150L Temperature control range: 15~50℃ temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃ (same level) Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(1000TPS-3)

    Internal volume: 1000L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(500TPS-3)

    Internal volume: 500L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(500LTPS-2)

    Internal volume: 500L Temperature control range: 2~30℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 6000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~1w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(1000TPS-3)

    Internal volume: 1000L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Stability chamber Stability Chamber(150L+150L)

    Humidity:20~95%RH Capacity:320L

Beijing Labonce Themostatic Technology Company

Professional Technology , Good Products

Email: Sophia@labonce.com FDA/ICH stability Chamber

© 2008-2026 Beijing Labonce Themostatic Technology Company All Rights Reserved

Online contact

Online contact

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!