Internal volume: 150L
Temperature control range: 15~50℃
temperature fluctuation: ±1.0℃
Temperature deviation: ±2.0℃ (same level)
Light range: Visible light range: 100 ~ 8000LUX
Total illumination is not less than 1.2 × 106Lux-hr
UV range: near-ultraviolet range: 0.84~5w/m²
Near-ultraviolet energy not less than 200w-hr/m²
UV wavelength: near-UV wavelength: 320~400nm

Product introduction

Labonce-TPS Photostability Chamber for Pharmaceuticals equipped with visible and near-ultraviolet lamps, can independently control the type of light source, and real-time printing and recording of visible light illuminance and near-ultraviolet radiation; visible and near-ultraviolet can be set up directly, automatically adjusted, and accurately control the two types of light sources.

Features of Photostability Chamber for Pharmaceuticals 

1. Illumination Control & Monitoring
Independently controls temperature, visible light, and near-UV light through imported controllers and dedicated illumination sensors.
2. Data Printing & Storage
Simultaneously prints temperature and illumination values, with over one year of built-in data storage for easy tracking and analysis.
3. Refrigeration System
Uses an imported hermetic compressor, offering reliable operation, long service life, and low operating noise.
4. Alarm & Protection Systems
Features on-site buzzer alarms for temperature deviations, independent over-temperature alarms, and automatic power cut-off protection.
5. Safety Protection
Equipped with multiple safety protections, including compressor overheating, overpressure, overload, and fan overheating protection.
6. Chamber Construction
Features a mirror-finish SUS304 stainless steel interior and a high-quality steel exterior with a durable spray coating.
7. Remote Alarm (Optional)
Optional SMS remote alarm system with power failure notification. Multiple units can share one SIM card for centralized monitoring.

Specification of Photostability Chamber for Pharmaceuticals 


Model

Temperature Range

( ℃ )

Capacity

(L)

Interior Dimensions

W×D×H(mm)

External Dimensions

W×D×H(mm)

Power

( kW )

Remarks 1

Labonce-150TPS-1

15 ~  50

150

650×490×500

830×790×1250

1.2

1  layer of light

Labonce-300TPS-2

15 ~  50

300

550×660×770

850×1030×1570

1.5

2 layers of light

Labonce-500TPS-2

15 ~  50

500

660×680×1110

880×1080×1880

1.8

2 layers of light

Labonce-500TPS-3

15 ~  50

500

660×680×1110

880×1080×1880

2.1

3 layers of light

Labonce-1000TPS-3

15 ~  50

1000

1360×490×1360

1620×910×1990

2.5

3 layers of light

Labonce-150LTPS-1

2 ~ 30

150

650×490×500

830×790×1250

1.5

1  layer of light

Labonce-500LTPS-2

2 ~ 30

500

660×680×1110

880×1080×1880

2.1

2 layers of light

Remarks 2

Visible Range: 100 ~  8000Lux, Deviation:4500±500Lux;UVA range:0.84 ~  5w/m2; (TPS)

Visible Range: 100 ~  5000Lux, Deviation:4500±500Lux;UVA range:0.84 ~ 1w/m2; (LTPS)

The total illumination ≥ 1.2×106 Lux •hr; UVA energy ≥ 200w •hr/ m2

Each of layer of light: Visible Light+UVA





SEND A MESSAGE

Related products
  • Photostability Chamber Photostability Chamber(150LTPS-1)

    Internal volume: 150L Temperature control range: 2~30℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃ (same level) Light range: Visible light range: 100 ~ 6000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~1w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(1000TPS-3)

    Internal volume: 1000L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(500TPS-3)

    Internal volume: 500L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber(500TPS-2) Photostability Chamber(500TPS-2)

    Internal volume: 500L Temperature control range: 15~50℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃ (same level) Light range: Visible light range: 100 ~ 8000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~5w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • Photostability Chamber Photostability Chamber(500LTPS-2)

    Internal volume: 500L Temperature control range: 2~30℃ Temperature fluctuation: ±1.0℃ Temperature deviation: ±2.0℃  Light range: Visible light range: 100 ~ 6000LUX Total illumination is not less than 1.2 × 106Lux-hr UV range: near-ultraviolet range: 0.84~1w/m² Near-ultraviolet energy not less than 200w-hr/m² UV wavelength: near-UV wavelength: 320~400nm

  • TH Series Constant Test Chamber 150TH-500TH

    Humidity:20~95%RH Capacity:150~500L

  • Comprehensive Stability Chamber Stability Chamber (220L+220L+480L)

    Humidity:20~95%RH Capacity:930L

  • JMH Series Drying Oven 245JMH

    TEMP:   RT+ 20~200℃ CAPACITY: 70L~1000L

Beijing Labonce Themostatic Technology Company

Professional Technology , Good Products

Email: Sophia@labonce.com FDA/ICH stability Chamber

© 2008-2026 Beijing Labonce Themostatic Technology Company All Rights Reserved

Online contact

Online contact

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!