Newsletter
Keep up with our latest news and events.
Enter your email and subscribe to our newsletter
Humidity:40~95%RH Capacity:150L~500L
Read moreItem NO.:
150-500CGS-FCProduct Origin:
CHINALabonce-CGS-FC Series Integrated Drug Stability Test Chamber (Combined Temperature + Humidity + Visible Light + Near-UV Control) Featuring an all-new structural design and high-quality imported components, this system ensures long-term stable operation with reliable performance.
❶ Internal Volume: 150L–500L
❷ Temperature Control: Range: 15–65°C Fluctuation: ±0.5°C Deviation: ±1.0°C (without light)
❸ Humidity Control: Range: 20–95% RH Fluctuation: ±2.0% RH Deviation: ±3.0% RH (without light)
❹ Visible Light Range: Adjustable: 100–8000 LUX Standard: 4500±500 LUX Total illuminance: ≥1.2×10⁶ Lux·hr
❺ Near-UV Range: Adjustable: 0.84–5 W/m² Total energy: ≥200 W·hr/m²
❻ UV Wavelength: 320–400 nm
❼ Control System: Touchscreen controller (centralized control for temperature, humidity, visible light, near-UV).
❽ Data Printing: Prints real-time values for all four parameters (temperature, humidity, visible light, near-UV).
❾ Temperature & Humidity Controller: 7-inch+ color touchscreen, programmable, with 3-level access control and audit trail.
❿ Humidity Sensor: Imported capacitive sensor, direct detection, maintenance-free.
⓫ Refrigeration Compressor: Inverter-driven fully sealed compressor (imported), long lifespan, low noise, 50%+ energy savings.
⓬ Data System: Stores data for ≥5 years; prints model number, temperature, humidity, and illuminance values.
⓭ Alarm System: On-site alarms (buzzer for deviations in temp/humidity/light). Independent over temperature alarm. Remote SMS alerts (including power failure alerts).
⓮ Chamber Material: Inner wall: Mirror-finish stainless steel (304). Outer shell: High-quality steel plate with powder coating.
⓯ Dual-Door Structure: Inner tempered glass door (for observation). Outer light-blocking door (sealed against external light).
⓰ Dual Protection: Dual dry-burn prevention system. Independent over-temperature protection (auto power cutoff).
⓱ Safety Features: Compressor overheat/over pressure/overload protection. Fan overheat protection.
⓲ Power Supply: AC 220V±10%, 50Hz
⓳ Operating Environment: Recommended: ≤30°C (optimal: ≤25°C). Range: +5–35°C.
⓴ Special Note: Consult the PDF and WORD icons below online to download the color page related information on this page.
Model |
Temperature Range( ℃ ) |
Humidity Range (RH) |
Capacity (L) |
Interior Dimensions W×D×H(mm) |
External Dimensions W×D×H(mm) |
Power (kw) |
Shelf (Standard) |
Labonce-150CGS |
15~65 |
20~95% |
150 |
600×405×620 |
780×830×1480 |
1.2 |
3 |
Labonce-250CGS |
15~65 |
20~95% |
250 |
600×500×830 |
780×880×1650 |
1.5 |
3 |
Labonce-400CGS |
15~65 |
20~95% |
400 |
600×700×950 |
780×1060×1750 |
2.0 |
3 |
Labonce-500CGS |
15~65 |
20~95% |
500 |
680×680×1080 |
860×1050×1850 |
2.2 |
4 |
Remark |
1) It has four functions: temperature, humidity, visible light and near ultraviolet. The illuminance measurement is equipped with visible light and near ultraviolet sensors, which realizes automatic illuminance control, and automatic printing and storage of visible light and near ultraviolet values. 2)Visible light range: 100 ~ 8000Lux, illuminance deviation: 4500 ± 500Lux, the total illuminance of the illumination test shall not be less than 1.2×106 Lux·hr; near ultraviolet range: 0.84 ~ 1.0 w/m2 , the total illuminance of the near ultraviolet shall not be less than 200w·hr/m2. |
Previous :
Stability Chamber(3000L)Next :
Stability Chamber(<500L)Pay attention to WeChat