Humidity:40~95%RH Capacity:150L~500L
Read moreItem NO.:
800TH~1000THProduct Origin:
CHINA
❶ |
Reference standard: GB/T 10586-2006 Humid heat test chamber technical conditions; |
❷ |
Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; |
❸ |
Insulation material: Overall high-density polyurethane foam technology, with good insulation and moisture retention performance; |
❹ |
Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; |
❺ |
Refrigeration system: Imported fully enclosed compressor, high efficiency, low noise, long life; |
❻ |
Control system: programmable color touch screen controller with multi-segment program and fixed value function; |
❼ |
Data management :Electronic data storage function, which can export data through a USB flash drive; |
❽ |
Humidity control: Original imported capacitive humidity sensor, high precision, low drift, long service life, maintenance free; |
❾ |
Safety device: Anti dry burning protection system, independent overtemperature protection system, on-site buzzer alarm; |
❿ |
Other configuration: Test hole、Rubber plug、Mobile casters、Door lock、Viewing Window; |
⓫ |
Temperature control Precision: temperature fluctuation<± 0.5 ℃ ; Temperature deviation<± 2.0 ℃ ; |
⓬ |
Humidity control Precision: humidity fluctuation<± 3% RH; Humidity deviation<± 3% RH (control humidity>75% RH),Humidity deviation<± 5% RH (control humidity ≤ 75% RH); |
⓭ |
Environmental temperature:+5~35 ℃ ; |
⓮ |
Power: AC220V ± 10% 50Hz; |
⓯ |
Optional: printer. |
⓰ |
Optional: Temperature- humidity deviation, sudden power failure , control by Remote SMS alarm. |
⓱ |
Optional: Temperature- humidity deviation, sudden power failure , control by Remote SMS alarm. |
Model |
Temperature Range ( ℃ ) |
Humidity control range (RH) |
Capacity (L) |
Interior Dimensions(mm) W×D×H |
External Dimensions(mm) W×D×H |
Power ( kW ) |
Shelf (Standard) |
Remarks |
Labonce-150TH-T |
0 ~ 100 |
20~95% |
150 |
600×405×620 |
780×830×1480 |
1.5 |
3 |
Equipped with high temperature resistant capacitive humidity sensor |
Labonce-250TH-T |
0 ~ 100 |
20~95% |
250 |
600×500×830 |
780×870×1650 |
1.8 |
3 |
|
Labonce-400TH-T |
0 ~ 100 |
20~95% |
400 |
600×700×950 |
780×1060×1750 |
2.2 |
3 |
|
Labonce-500TH-T |
0 ~ 100 |
20~95% |
500 |
680×680×1080 |
860×1050×1850 |
2.5 |
4 |
|
Labonce-800TH-T |
0 ~ 100 |
20~95% |
800 |
1200×490×1360 |
1390×890×1960 |
3.0 |
4 |
|
Labonce-1000TH-T |
0 ~ 100 |
20~95% |
1000 |
1400×510×1400 |
1590×890×1980 |
3.5 |
4 |
Previous :
Constant Temperature Chamber(50CT)Next :
Constant Temperature & Humidity Chamber(150CH~500CH,15~60℃)Labonce- BI series of biochemical incubator is applied in scientific research and production departments such as environmental protection, health and epidemic prevention, agriculture, animal husbandry, and aquatic products, drug testing, and cell culture. ◆ Reference standard: GB/T 28851-2012 Technical conditions for biochemical incubators; ◆ Air-way System: The newly air-way system designed achieves uniform of temperature form different parts inside the chamber; ◆ Chamber Materials:The exterior is coated with high quality steel plate,The liner is made of mirror stainless steel 304, no pollution source, easy to clean; ◆ Refrigeration system:Imported fully enclosed industrial compressor, high efficiency, low noise, long life; ◆ Control system:LCD temperature controller; ◆ Data management :Configure needle type micro printer and electronic data storage function,support to use U disk to export the data; ◆ Safety device: compressor overheat and overpressure overload protection, independent overtemperature protection alarm system,On-site beeping alarm; ◆ Other configuration:Test hole、Rubber plug、Mobile casters; ◆ Controlling Temperature Precision:Temperature Fluctuation:High temperature ±0. 5℃; Low temperature ±1.0℃ ; Temperature Uniformity ≤ 2.0℃(@37℃); ◆ Environment Temperature:+5 ~ 35℃ ; ◆ Power:AC220V±10% 50HZ; ◆ Optional: ① UV sterilization system; ② Three- level permission color touch screen controller; ③ SMS alarm; ④ Humidity display function. Name Model Temperature Range ( ℃ ) Capacity (L) Interior Dimensions(mm) W×D×H External Dimensions(mm) W×D×H Power ( kW ) Shelf (Standard) Remarks Biochemical Incubator Labonce-150BI 0 ~ 60 150 520×460×600 640×700×1250 0.5 3 150-250L Configure obser vation window Labonce-250BI 0 ~ 60 250 520×460×1050 620×690×1650 0.6 3 Labonce-400BI 0 ~ 60 400 600×700×950 780×1060×1750 1.0 3 400-2000L Configured with built-in glass doors Labonce-500BI 0 ~ 60 500 680×680×1080 860×1050×1850 1.2 4 Labonce-800BI 0 ~ 60 800 1200×490×1360 1390×890×1960 1.5 4 Labonce-1000BI 0 ~ 60 1000 1400×510×1400 1590×890×1980 2.0 4 Labonce-2000BI 0 ~ 60 2000 1500×970×1400 1710×1380×1990 2.5 4 Biochemical Incubator Labonce-250BI-H 0 ~ 60 250 520×460×1050 620×690×1650 0.6 3 With humidity display Labonce-800BI-H 0 ~ 60 800 1200×490×1360 1390×890×1960 1.5 4